I had an engineer recently tell me he
was working on a project where they needed to minimize RO brine volume and he
wanted at least 90% recovery, so please quote a 3-stage system… Antiscalant
projections on the raw water quality showed 78% recovery at best, even with acid
dosing. The chemistry won’t allow any higher recovery on this water on matter
how many stages the RO system has, and don’t get me started on whether CCRO can
do better (I’ll discuss this later).
That is the fourth inquiry like
this I have had in the past 6 months and the second from this engineer who is
finding it hard to understand the limitations on recovery… so I thought I would
put the explanation in print here.

Before you start to think of how
many stages you need to design the RO system for, you first need to look at the
water chemistry to see what recovery is possible. All the antiscalant
manufacturers have projection programs where the raw water quality data is
entered, an antiscalant is selected and from the empirical data the program calculates
the maximum recovery that can be achieved and what are the limiting salts. You
can adjust the feed pH to see the impact of pH correction and you can also
change some feed parameters so see how pretreatment will impact recovery. At
this point, stages do not even come into the equation. For a customer that
wants to get as high a recovery as possible, I also often ask the antiscalant
suppliers to do a projection for me, because sometimes they have a product I
may not be aware of or that is not part of the projection software version I
have.
PLEASE NOTE - INCREASING THE NUMBER OF STAGES DOES NOT ALLOW A HIGHER
RECOVERY THAN WHAT THE ANTISCALANT PROJECTIONS PREDICT!!! ALSO, INCREASING THE
NUMBER OF STAGES DOES NOT ALLOW A HIGHER RECOVERY THAN WHAT THE ANTISCALANT PROJECTIONS
PREDICT!!! Got the message??
Some antiscalant projection
programs incorporate calculations on RO unit arrays, but I prefer to first
optimize recovery then use the membrane manufacturer’s projection programs to
design the best array – I just feel more confident with the RO/NF system design
when I use the membrane vendor programs.
Now that I know the maximum
recovery that is possible determined by the water chemistry, not the number of RO
unit stages, I then go about working out how many stages are needed to achieve
this recovery. When designing an array for an RO system there are several
important design conditions that need to be accounted for, including crossflow
velocity and flux across the membrane elements. The projection programs have
built in warnings when these are too high or low. Operating outside the safe
ranges will result in membrane fouling.
A 2-stage RO system is limited to
up to 80-85% recovery because somewhere in this range you will violate the
minimum crossflow requirements for the membranes. When the crossflow is too low
you can get concentration polarization at the membrane surface resulting in
scaling. By adding a third stage you can reduce the number of housings required
in the first 2 stages to increase the crossflow velocity to within the desired
range and add back those housings via the third stage to maintain the desired
flux rate. For instance, rather than try achieving 85% recovery using a 4:2, 7M
array at an average flux of 15 gfd at a permeate flow of 175 gpm which sends
some low crossflow warnings for the first stage, you could change this array to
a 3:2:1, 7M 3-stage system which has the same flux but the crossflows are better
balanced across the membranes.
When attempting really high
recoveries, where the water chemistry allows, you may even need to add a fourth
stage. Another option to adding stages, is to recycle some Stage 2 concentrate
back to the Stage 1 feed to increase cross flow velocity and allow higher
recoveries but this increases the concentration of feed water constituents and
subsequently the permeate quality is worse.
And CCRO is not the silver bullet either!
Now a short discussion on ClosedCircuit RO (CCRO). The recovery rate of a CCRO system, like conventional RO, is
limited by the chemistry and how much the feed water salts can be concentrated with antiscalant addition.
In most cases, the recovery of CCRO is predicted by the antiscalant projections exactly the same as for conventional RO. Because CCRO purges the recycled
concentrate every 15-45 minutes, if silica is the constituent limiting the
recovery, due to the saturated silica concentration being reached towards the
end of this cycle and the slower induction time for silica to precipitate once
it reaches saturation (say 10 minutes), CCRO can push past the maximum recovery
predicted by antiscalant projections. For that scenario, CCRO will achieve a higher recovery than a conventional RO system.
But for more common scalants such as
calcium carbonate and calcium sulfate, the induction time is just seconds and the
CCRO process offers no advantage over conventional RO if these are the limiting salts. I would be happy for
someone to give me a good technical explanation how CCRO can achieve a higher
recovery when CaCO3 and CaSO4 are the limiting salts because from my investigations
I have not found one. Don't get me wrong, I'm all for new technologies that can improve on the recovery of conventional RO systems, but I also want to see good science on how this is achieved.
The main message I want you to get
from this post though is the following:
INCREASING THE NUMBER OF STAGES
DOES NOT ALLOW A HIGHER RECOVERY THAN WHAT THE ANTISCALANT PROJECTIONS PREDICT!!!