How do you build the Best Commercial RO Membrane System?

Recently I was talking to a consulting engineer about the membrane systems we build and he said “so you don’t actually manufacture any of the components, you just assemble the system?” I was a little taken aback with this comment as this is pretty much what all membrane OEMs do. Either the engineer didn’t understand how membrane systems are put together or he had been sold on one of the few OEMs that manufacture a few of the components used to build the membrane system. I look at a bill of materials for a RO system and there are over 300 different components …… So if out of all of these an OEM manufactures the feed pump and pre-filters is that going to be a better RO system?

The beauty of being a completely independent OEM (Original Equipment Manufacturer) is that you can select the best available components to build a membrane system for a specific application.
You can choose a pump that is most energy efficient and perfectly sized for a skid, rather than one OEM that must use multiple feed pumps per skid because of limitations in pump sizes that it manufacturers. When new components become available, the independent OEM (typically the smaller more nimble OEMs) can quickly incorporate these into a system design to the benefit of the end user.

And next time I see a spec that says the Reverse Osmosis OEM must also manufacture the membrane I will feel sorry for the end user who will have been duped into overpaying for a product no better than what they could have bought from an independent OEM. RO membranes are a commodity and there are several suppliers such as Toray, Dow/Filmtec, Hydranautics and CSM that sell to OEMs, offer very good technical support and provide prorated warranties for the membranes of up to 5-years depending on the application. I was actually visiting a manufacturing facility of one of the aforementioned membrane companies and was surprised to see a stack of boxed membranes private labeled for an OEM who claimed to make their own membranes…. Even if the company did make its membranes, with the ability to purchase from multiple RO membrane vendors, the independent OEMs can choose the best membrane available for an application, get very competitive pricing and pass on a more economical RO system to the end user.

Smaller systems are often the biggest losers when purchasing a membrane system when they or their engineer are convinced that larger OEMs that also manufacture some of the components will provide a more reliable system with better technical service. In reality, the larger OEMs may be encumbered with outdated equipment they have to use which is more expensive than components available from other independent suppliers. And don’t start me on the technical service….Just talk to a small system that has purchased equipment from a large OEM recently and see what they say!

Monday, October 29, 2012

Dow and Toray UF Modules Level Bidding Playing Field

Is commoditization of the MF/UF market finally here?

The specifications for a project that recently bid in South Dakota were a sign that the municipal Microfiltration/Ultrafiltration (MF/UF) membrane market is finally moving towards commoditization. It is the first MF/UF specification that I have seen where there were both prequalified OEMs and prequalified MF/UF membrane modules, allowing the OEMs to bid using any of the listed modules. This type of specification is common in the commoditized NF/RO market, but has been almost non-existent as far as I am aware in the municipal drinking water market. The modules listed in the specification were the following PVDF, hollow fiber membranes:

• Siemens/US Filter L20V
• Pall Microza MF
• Toray HFS
• GE Zeeweed 1500
• Dow UF (SFD 2880)

Of course Siemens, Pall and GE have exclusive access to the L20V, Microza and Zeeweed 1500 modules respectively, but any of the listed OEMs could bid with the Toray and Dow UF modules. Additional OEMs listed were Wigen Water Technologies and H2O Innovation, both of whom have municipal UF installations using Dow and Toray membranes.

There were some unique circumstances with this bid that allowed such a specification, where all of the above membrane modules had previously been piloted on Missouri River water in the Dakotas, which was also the source water for this new plant. All of the qualified OEMs had at some point conducted a pilot study under the supervision of Bartlett & West (B&W), the consulting engineer managing the project and therefore were not required to pilot for this project. To be qualified, OEMs also had to have installed at least three surface water MF/UF systems between 1 – 5 MGD.

Customers Win!

 With such a competitive bidding environment and probably due to the system size (2.7 MGD), only one of the ‘big three’ OEMs bid for the project. Not surprisingly, the lowest bidder (and subsequently the winner) bid with Dow UF modules and was more than 25% lower in price than the bidder with a proprietary membrane. Worth noting is that even the highest bidder was almost 30% below the engineer’s estimate, evidence of how much value can be achieved for customers with more competitive bidding. This is particularly the case for smaller systems that historically been reluctantly served by a few larger OEMs, resulting in high prices. Now that Dow and Toray offer their UF modules to multiple OEMs, smaller OEMs such as Wigen and H2O are aggressively pursuing this segment of the market, resulting in lower prices and, I am sure, happy customers!

Dow UF System at Fort Thompson, SD
OEM - Wigen Water Technologies
You have to give credit to B&W for writing such a spec which has saved their customer a significant amount of money. B&W's client base is small to medium municipalities and they have found a way to make advanced water treatment technologies more affordable to these customers. It is unlikely you would see such a spec from a global consulting engineering firm, but then these large firms rarely deal with the smaller municipalities anyway.

While it may not be possible to bid this sort of specification for many water sources, there are many shared water supplies where multiple membrane types have been tested and OEMs have experience, allowing a more competitive bidding process. With a number of proven pressurized PVDF hollow fiber membrane now on the market, and with system designs becoming more standardized in terms of integrity testing, block and bleed valving, recovery rates and cleaning regimes, it is becoming possible to write more standardized specifications for pressurized outside-in UF modules, much like for NF/RO systems.

The end result, as the MF/UF market moves towards commoditization, is lower membrane module prices and lower system prices which means high quality drinking water becomes more affordable and accessible, particularly for smaller systems who have historically had to bear the brunt of an uncompetitive marketplace – a great example of competition benefiting the end consumer!

Tuesday, July 24, 2012

Has Journal AWWA Lost its Way?

Is new format a step forward or backward?

I used to keep the latest copy of the Journal AWWA (JAWWA) in my briefcase for a month or two as I gradually read the technical articles. Sometimes I would have several issues backed up if there were a lot of articles of interest I wanted to read.

Last week, as I flicked through the most recent issue in about 30 minutes, I wondered if the new format of extended abstracts rather than full technical papers is a step backward for the traditional readership. I was also left with nothing to read for the remaining hour of my plane trip….A couple of the abstracts looked interesting and if the full papers were there, I would have read them, but for the new format I have to go online to find the full articles. Not really practical on a plane or in the lunch room when I typically read JAWWA. Maybe I am old school, but I am not going to read a technical paper direct from my computer screen anyway, so that means I now have to print it and carry it around with me so it is available when I get time to read it on a plane or at lunch – not going to happen! The end result is I am less informed about new technical developments in the Water industry, one of the main benefits JAWWA previously had to offer me.

I can’t recall the reason the American Water Works Association gave for the new format. I probably should have said something when this was announced but I didn’t realize at the time how the changes would impact me. JAWWA is now slipping towards the tabloid status of WE&T, Waterworld and Water & Wastes Digest, which have more room for advertising and less for substance. Was the change to JAWWA to allow the inclusion of more articles to keep authors happy or allow more advertising or both? Has it been worth it?

AWWA had better be careful it does not lose members out of this change. When I was living in Australia and did not have access to AWWA conferences and Section resources, the main reason I was an AWWA member was primarily to get the Journal followed by access to the book store and technical library. I was speaking to a consultant at the recent AWWA Annual Conference in Dallas about how difficult it is to keep up with the technical reading and every few months he said he went through his pile of magazines and threw out everything except JAWWA which was a must read. I was the same, but with the new format, my JAWWA pile now goes down a lot faster – in fact I don’t have a pile now… Is that a good thing or a bad thing? Will that consultant soon also be throwing out JAWWA without looking through it?

Personally I think JAWWA is losing the technical high ground it had over other water industry publications and if it moves too far away from what previously differentiated it from these publications, will lose readership of the very people it needs to attract its advertisers and members.

Friday, April 13, 2012

Serious Challenge to ‘Big Three’ at 2012 Membrane Technology Conference

Papers and Booths from new MF/UF OEMs indicate grip of Big Three is loosening

It is official; the grip of Pall, Siemens and GE on the municipal microfiltration (MF) and ultrafiltration (UF) market is loosening! Based on the presentations showcasing MF/UF systems at the AWWA/AMTA 2012 Membrane Technology Conference and Exposition in Glendale, Arizona, Feb 27-March 1, it was clear to all attendees that in the past year new OEMs have made significant strides in entering the market. Systems using Toray hollow fiber UF membranes appear to have gained the most traction with Dow UF membranes close behind.

A poster from Wigen Water Technologies [1] showcased 1 and 2 MGD systems in North Dakota using Toray UF modules that started up in early 2011. These systems have been operating well and to-date have not experienced a single membrane fiber breakage. A URS poster [2] titled “It’s not Just the Big Three Anymore…” featured a project for a 7.2 MGD UF system in Ohio where prices from OEMs using Toray and Dow membranes were significantly lower than the Big Three, and pilot performance was as good or better. Following pilot testing, a system using Toray UF membranes was subsequently selected and is in construction.

In addition to the presentations, Kruger used the AMTA/AWWA Conference to launch its new UF system utilizing the Dow UF module while a number of other OEMs had booths showing that they also were entering the market using either the Toray or Dow UF modules.

It will be very interesting to see in the next 24 months which OEMs are most successful in gaining a foothold in the MF/UF market alongside the Big Three. Will this market move towards being commoditized like the NF/RO market where a particular membrane module and skid design will be specified and a number of qualified OEMs can bid to build systems using this module and design? I don’t think we will get to this point in the near future, but I am sure those OEMs using proprietary membranes or with exclusive supply arrangements will be getting a little nervous!

References

Bourke, M.F.; Guibert, S; “Performance of First Large Scale U.S. Ultrafiltration Systems Using Toray Membranes”, 2012 Membrane Technology Conference & Exposition, Glendale AZ, Feb 27 – March 1.

Shoaf, R.T; Cook, J.M.; “It’s Not Just the Big Three Anymore – Pilot Testing and Membrane Selection for the Delaware Ohio Integrated Membrane Facility”, 2012 Membrane Technology Conference & Exposition, Glendale AZ, Feb 27 – March 1.


Sunday, December 25, 2011

Microfiltration & Ultrafiltration Integrity: Don’t believe breakages happen!

Myth spreads that a certain amount of MF/UF Fiber Breakages are acceptable...

I’m back, and I’m mad! I started this blog with the intention of being as informative and impartial as possible on water technology topics, but my New Year’s resolution is to spice it up a little and forget about being PC. I am fed up with the perceived mystique around building a reliable MF or UF system for drinking water applications after just losing out to Pall on a UF project because my company was considered ‘not qualified’ to have our price considered. I have to hand it to the ‘big three’ MF/UF manufacturers, Pall, Siemens/Memcor and GE/Zenon. They have certainly done a good job in convincing consultants and owners that manufacturing a MF/UF system is so complicated that only established players in the market should be considered. They were the first to get established in the market, so they have the right to leverage that advantage, but they can only pull the wool over the industry’s eyes for so long! There are now some bloody good alternative UF membranes out there on the market, better than most of the established products, and the sooner this is realized, the sooner the end users will reap the benefits.

In an interview for the project we were recently unsuccessful on, the owner’s consultant (from one of the biggest municipal engineering firms in the world) implied that because we were a small firm and did not have standardized UF system designs like our larger competitors, our custom designed systems would potentially have reliability issues because we did not have experience with the exact same system configuration operating in the field. He then went on to question why we did not have a large list of exceptions to the specification we bid to. The reason we didn’t have exceptions is because we bid with a design that matched the spec rather than tried to squeeze a standard UF skid design into their spec – duh! The big membrane companies have done a good job in brainwashing the engineers on why a standard design is better than a custom system for small skid mounted applications. The reality is that the big firms cannot cost effectively custom design a small skid mounted UF system and the only way they can be successful on these smaller projects is to have the smaller custom design firms disqualified. Good luck in now trying to put that square peg in a round hole and getting an off-the-shelf design to operate as specified!


Hollow Membrane Fiber Breakage
 Why then is our small company successful in winning similar sized NF and RO projects with the same global engineering firms? Is it because with NF and RO considered more of a commoditized market, the engineers assume these are simpler to build than MF/UF systems? As a company that manufactures UF as well as NF/RO systems, that is complete BS! UF systems are actually simpler to manufacture. The only challenge has been getting a UF membrane module that will not fail integrity tests. Two of the major MF/UF system manufacturers have had significant problems in recent years with membrane breakages, but they have done a very good job in convincing the market that some membrane fiber breakages are par for the course. Poppycock!! There are now UF membranes on the market from Toray and Inge that have no recorded fiber breakages to date, including systems we have built using these membranes. It is the established companies that manufacture their own proprietary MF/UF membranes that are having the integrity issues and want the market to believe that some level of membrane fiber breakages is inevitable (Stratton, et. al.). These companies are probably scared to death at the more robust UF membranes such as Toray’s that have entered the market and are available to OEMs (see Municipal Ultrafiltration Heads Towards Commoditization).

The large MF/UF system OEMs have largely left the packaged NF/RO market because they are not cost competitive, especially for skid mounted systems. Ultimately, they will not be competitive in the skid mounted UF market either – they actually aren’t currently cost competitive, but are surviving in this market through scare tactics to keep owners and engineers from considering the more cost effective alternatives. Sooner than you think, the time will come when at least two of the ‘big three’ will be squeezed out of the skid mounted MF/UF market. The big winners will be end users who will get higher quality UF systems at a much lower price.

References:
Stratton, Richard and Chang, Yujung (2011), “Membrane Fiber Breakage: Case Histories, Probable Causes, and Possible Solutions”, 2011 American Water Works Associations Membrane Technology Conference, March 28-31.

Thursday, June 23, 2011

Municipal Ultrafiltration Heads Towards Commoditization

Market entry of Toray and Dow signal reign of 'Big Three' may be over!

The municipal market for ultrafiltration (UF) and microfiltration (MF) membranes has long been dominated by what the industry terms the ‘Big Three’; Siemens (previously US Filter), GE (previously Zenon) and Pall. Other players such as Koch and Aquasource, who made some early inroads into the North American market, have largely fallen by the wayside as inside-out PES UF/MF membranes have lost favor for various reasons. This has left the Big Three (B3) to divide up the North American UF/MF market, with other manufacturers rarely qualified to bid for these projects.

The dilemma for consultants and owners who want to purchase a UF/MF system is that the proprietary systems offered by the B3 each have their own unique characteristics. Therefore to create a competitive bid situation, at least two of the B3 need to be trialed to specify design parameters, unlike commoditized reverse osmosis (RO) membranes that can be bid on by a number of manufacturers after a single pilot study.

Finally, as Bob Dylan sang, The times they are a-changin’. The introduction of outside-in, PVDF UF modules to the market in the past few years by RO Membrane behemoths Dow and Toray has allowed OEMs, which have had a long relationship with these companies in the RO market, to now enter the UF market….and the timing could not have been better! I have been told by the larger engineering consulting firms that 5 years ago they would not have considered a UF OEM that did not have years of operating data from systems of comparable size to the project they were working on; that pretty much ruled out all but the B3. For various reasons including the consolidation of some of the B3 into larger more bureaucratic corporations, rising prices especially for smaller systems and some questions over long term membrane integrity for the submerged systems, many consultants are now willing to overlook previous experience requirements.

While the Dow and Toray UF modules are not interchangeable like their RO modules due to different positions of the feed and permeate ports (see Figure 1), availability is not restricted exclusively to a single OEM which allows more than one OEM to bid for a project using the same modules. This is the beginning of a huge change to the MF/UF market place, making bidding much more competitive and potentially allowing owners to conduct one pilot trial but still have multiple bidders as is the case for RO systems. This will be a relief to consultants and owners who in the past have had to endure expensive and lengthy pilot test programs to overcome the difficulty in comparing the proprietary MF/UF offerings.
Figure 1: Comparison of Toray and Dow UF Modules
Within a year of the Toray UF module receiving California Department of Public Health approval, several bids have been awarded to OEMs using this membrane and the first North American installation, a 2.0 MGD system built by Wigen Water Technologies, was started up in North Dakota earlier this year. This is the first of three UF systems between 1.0 and 4.5 MGD using the Toray module that Wigen is starting up in 2011. Wigen also has a 2.0 MGD system using the Dow module scheduled to start up in South Dakota in early 2012. At least two other OEMs have been awarded projects using these modules that are scheduled to start up in 2011.

So the times really are a-changin’ and the Big Three’s stranglehold on the MF/UF market is starting to weaken with the availability of quality PVDF outside-in UF modules to OEMs that are familiar with competing in the commoditized RO system market. While we are still not at the point of interchangeable UF modules from multiple manufacturers, the availability of the same UF modules to multiple OEMs will make the market much more competitive resulting in reduced costs for end users.

Monday, April 4, 2011

Is Suspended Ion Exchange (SIX®) Ready for Market?

In 2010 a new water treatment technology called Suspended Ion Exchange (SIX®) signaled its entrance into the North American water treatment market with presentations at several water industry conferences. SIX® was developed by PWN Technologies, a subsidiary of Netherlands based PWN Water Supply Company North-Holland, primarily as a pretreatment process for the removal of natural organic matter (NOM) prior to membranes.

PWN states (1) that SIX® overcomes limitations of traditional fixed bed ion exchange contactors, such as fouling and blinding of resin pores and surfaces with organic and colloidal matter, and is able to tolerate fluctuations in raw water characteristics. PWN also claims SIX® has advantages over the MIEX® Process, another suspended ion exchange process developed by Orica Watercare Inc., through improved efficiency of the ion exchange contactor and regeneration process while enabling the use of a range of commercially available ion exchange resins, unlike the MIEX Process which uses a proprietary resin.

Before I go any further, I will let you know that I did previously work for Orica Watercare and was involved in the development of the MIEX Process. As I no longer have any allegiances to my previous company, I will be making as impartial a review of SIX as possible. I believe my experience in the commercialization of the MIEX process also helps to provide a unique insight into the readiness of SIX for market.

How SIX® Works

Figure 1: Flow Diagram of the SIX® Process (Reference 2)
The SIX ion exchange vessel consists of vertical cylindrical contact chambers containing baffles and mixing paddles to distribute flow and ensure effective mixing. These continuous mixing chambers are used in series with the object of approaching the ideal contactor kinetics of a plug-flow reactor1. An anion exchange resin is injected into the raw water feed, suspended in the contact tanks and then removed after the second contact tank where it is regenerated in a separate regeneration process. The regeneration process consists of a number of mixed regeneration vessels where a brine solution is contacted with the resin. The brine solution is recycled a number of times to reduce waste volumes. Regenerated resin is then transferred to fresh resin tanks where it is then added back to the raw water feed. PWN has also investigated the use of Nanofiltration to separate NOM from the spent brine regenerant and further reduce waste volumes but the reported pilot results have only seen up to 67% removal of the NOM which would not allow the permeate to be suitable for resin regeneration (2).

The potential advantage of suspended ion exchange is that turbidity can pass through the contactors without impacting process operation, thus allowing SIX to be used as a pretreatment process. In addition, the efficient contacting of the resin in a plug-flow reactor configuration and subsequent ‘exsitu’ regeneration can potentially result in significantly lower brine waste volumes compared to conventional fixed bed ion exchange systems.

This background information has been gleaned from papers and presentations I attended at the 2010 IWA Leading Edge Technologies Conference and the 2010 AWWA WQTC Conference. No additional information is readily available on the process, with little detail on PWN’s website. It is therefore difficult to make a proper quantitative assessment of the true benefits of SIX and the readiness of the technology for market. The kinetic modeling that has been performed is excellent and demonstrates that the plug-flow reactor configuration is a more efficient means of facilitating ion exchange – but most chemical engineers could have told you that without the testing. Reported percent removals of NOM and nitrate are all based on testing performed on one water source. I would like to see more testing conducted on different water sources with a range of characteristics, including different NOM characteristics and ionic compositions, for a better indication of the robustness of the process.

Show me a Mass Balance!

My major beef with the available data is the absence of any mass balance data to quantify claims of regeneration efficiency, low waste volumes and low salt use. The data presented at the IWA Conference just didn’t add up. Dissolved organic carbon (DOC) concentrations in the waste brine were reported only as ‘greater than 300 mg/L’. How much greater… 350 or 500 mg/L?? There was no quantification of how much waste is produced and when I asked the presenter, a PWN representative stood up and said it was about 1 m3 per 5000 m3 treated. That is 200 gallons of waste per 1000 gallons of water treated - pretty impressive, but let’s look again at the waste TOC concentration to see if that makes sense. Assuming the waste TOC concentration was 400 mg/L in 1 m3 of waste; by mass balance the process is removing 400 grams of TOC per 5000 m3 of water treated, or 0.08 mg/L – not very impressive considering the raw water TOC was reported at about 6.0 mg/L. The IWA paper shows a DOC reduction by SIX of about 3.0 mg/L, which from my experience with anion exchange is reasonable. By mass balance, if the waste DOC concentration is 400 mg/L, the waste volume should therefore be more of the order of 37 m3 per 5000 m3 (7,500 gallons per million gallons of water treated) – unless the SIX process is also eating DOC…..

Figure 2: SIX® Pilot Plant (Reference 2)
My final concern is the regeneration process. It looks complex to me (Figure 2). Claims that this is simpler than the MIEX process are outdated by about 6 years. Significant enhancements have been made to the ‘exsitu’ regeneration process used by the MIEX technology since the first full-scale system started up in 2001 resulting in substantial reductions in waste volumes and simplification of operation. SIX still has to go through this learning curve and the sooner PWN can get a continuous demonstration plant operating the sooner it can start to iron out the operability bugs that will inevitably be found.

Despite my above reservations, I think SIX has great potential but it will be a few years yet before the technology is ready for widespread adoption. It would be great for the water industry if the MIEX technology had a truly competitive suspended ion exchange process to drive down costs to customers, speed up process improvements and allow ion exchange pretreatment to be competitively bid. This would be similar to when Memcor developed its submerged membrane process to counter its erosion of market share by Zenon’s Zeeweed process in the late 1990’s. To successfully launch SIX in North American, PWN should take a look at how the MIEX process was brought to market, including initiating pilot studies on a number of different water sources with the participation of locally respected academics and consulting firms and establishing a full-scale demonstration facility ASAP!

1. Friend-Gray, O.P.; Malley, J.P. Jr; “Suspended Ion eXchange (SIX®) for Pre-treatment in Advanced Oxidation and Membrane Water Treatment Systems”, Proceedings of IWA Leading Edge Technologies Conference, Phoenix AZ, June 2010.

2. Friend-Gray, O.P.;”Optimization of the Suspended Ion eXchange (SIX®) for Pre-treatment”, Proceedings of the AWWA Water Quality Technology Conference, Savannah GA, November 2010.